Special Options:
- Single & multiple insulator
- Duplex and triplex
- Fish spine beads and crimps on tails
- Staggered junctions
- Insulators available separately
- Material Certificates
| Type Designation: |
BTE
|
| Temperature Range: |
-200 to 1200°C
|
| Common Sensor Types: |
K, J, N, T, E
|
| Common Diameters: |
Ø 0.15mm to 3.25mm, SWG sizes
|
| Insulator Sizes: |
Oval or Round, Ø 3.0 to 12.0mm
|
| Common Insulation: |
Recrystallised alumina, Pythagoras
|
| Common Stranding: |
Single Strand
|
| Tail Length: |
30mm
|
Delivery time: 1 week, subject to stock availability.
We ship to the following countries:
United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States
Shipping rates:
• £15 for orders from UK Mainland.
• £25 for orders from UK – Highlands & Islands.
• £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
• £37 for orders from France and Germany.
• £42 for orders from Switzerland.
• £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
• £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
• £49 for orders from Iceland.
• £51 for orders from Finland, Sweden and Greece.
• £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
• £61 for orders from United States and Canada.
• £63 for orders from Liechtenstein.
• £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
• £90 for orders from India.
• £103 for orders from Brazil.
Don’t see your country listed?
We ship worldwide. Contact us for a shipping quote and delivery timeframe.
• +44 (0) 1246 261 999
• websales@peaksensors.com
Q: What is a Base Metal Thermocouple Insulated Element?
A: A Base Metal Thermocouple Insulated Element is a replacement thermocouple sensing element insulated in ceramic and designed for incorporation into sheaths, protective tubes, and industrial equipment assemblies.
Q: What is the Base Metal Thermocouple Insulated Element used for?
A: The Base Metal Thermocouple Insulated Element is commonly used for replacement of existing thermocouple elements, assembly into ceramic insulators and protective sheaths, industrial temperature sensing equipment, furnace and process plant applications, and OEM sensor manufacture and repair.
Q: What temperature range can the Base Metal Thermocouple Insulated Element measure?
A: Depending on the thermocouple type selected, the element is suitable for temperatures up to approximately 1250°C, making it suitable for many industrial high-temperature applications.
Q: Which thermocouple types are available?
A: Common base metal thermocouple options for the Base Metal Thermocouple Insulated Element include Type K, Type J, Type N, Type T, and Type E. These options cover a wide range of industrial temperature measurement requirements.
Q: Why is ceramic insulation used?
A: Ceramic insulation provides electrical isolation, high-temperature resistance, and mechanical support for thermocouple wires. It is suitable for installation into sheaths and protection tubes, ensuring reliable performance in industrial environments.
Q: What are the benefits of an insulated element?
A: Key benefits of the Base Metal Thermocouple Insulated Element include easy replacement of worn elements, low thermal mass for responsive measurements, simple integration into custom assemblies, flexible installation options, and cost-effective sensor maintenance and repair.
Q: What insulation formats are available?
A: Insulated thermocouple elements are available with round ceramic insulators, multi-hole ceramic insulators, and application-specific insulation arrangements. The insulation type can be selected to suit the assembly requirements.
Q: Can the Base Metal Thermocouple Insulated Element be customised?
A: Available options for the Base Metal Thermocouple Insulated Element include alternative thermocouple types, duplex constructions, different ceramic insulator sizes, custom element lengths, special junction configurations, and material certification documentation.
Q: What junction options are available?
A: The Base Metal Thermocouple Insulated Element can be supplied with grounded junctions, insulated junctions, and exposed junctions. These options allow optimisation of response time, durability, and electrical isolation according to the application requirements.
Q: Why choose the Base Metal Thermocouple Insulated Element?
A: The Base Metal Thermocouple Insulated Element offers reliable temperature measurement up to 1250°C with ceramic insulated construction and low thermal mass for rapid response. It provides easy integration into existing assemblies, multiple thermocouple type options, and flexible customisation possibilities. Suitable for replacement and OEM applications, the element is manufactured to meet REACH, RoHS, Conflict Minerals, and ISO 9001 quality standards.