High Temperature Thermocouple Assembly With Ceramic Sheath

This particular design of rare metal thermocouple is a very common temperature sensor that we regularly supply to high-temperature industries.

Application Notes:

  • High-temperature platinum temperature sensor
  • Designed specifically for your application/environment
  • Will withstand tough industrial use

Delivery time: Product made to order, delivery date to be confirmed.

Compliance:
✔ RoHS 3 (2015/863)
✔ Mineral Conflict
✔ ISO 9001 Certified

PQAL black on white ukas 9001 logo

Need some help?
Call us: +44 (0) 1246 261 999 websales@peaksensors.com

"*" indicates required fields

Name*
0
    0
    Your Basket
    Your basket is emptyReturn to Shop
        Scroll to Top
        Secret Link

        Technical Information

        Technical Diagram

        Shipping Information

        FAQs

        Quote Request

        Special Options:

        • Special materials available on request
        • Lining sheaths for porous materials available
        • Shanks fitted for head assembly
        • Adjustable or welded flange on shank
        • Pressure tight design available
        • Probe calibration
        • Material Certificates

        Appropriate Sheath Material:

        Material Max Temperature
        Recrystalised alumina (alsint) 1700° C
        Silicon carbide (recrystalised) 1600° C
        Sillimanite 60 1600° C
        Aluminous Porcelain (pythagoras) 1500° C
        Quartz 1500° C
        Silicon carbide (clay bonded) 1400° C
        Syalon 101 1000° C
        Type Designation:

        RMC

        Temperature Range:

        0 to 1700 ° C

        Common Sensor Types:

        R, S, B

        Common Sheath Size : (ØD)

        Ø 6.0, 8.0, 10.0, 12.0, 15.0, 17.0, 20.0, 25.0, 28.0mm

        Common Element Diameters:

        Ø 0.15mm to 0.5mm

        Shank material: (SL)

        Plated MS, stainless steel , chrome iron, alloy 600.

        Head options:

        ALA, KNE (IP68), HR AL BL (flip top), many others

        High Temperature Thermocouple Assembly With Ceramic Sheath

        Delivery time: Product made to order, delivery date to be confirmed.

        We ship to the following countries:
        United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States

        Shipping rates:
        • £15 for orders from UK Mainland.
        • £25 for orders from UK – Highlands & Islands.
        • £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
        • £37 for orders from France and Germany.
        • £42 for orders from Switzerland.
        • £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
        • £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
        • £49 for orders from Iceland.
        • £51 for orders from Finland, Sweden and Greece.
        • £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
        • £61 for orders from United States and Canada.
        • £63 for orders from Liechtenstein.
        • £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
        • £90 for orders from India.
        • £103 for orders from Brazil.

        Don’t see your country listed?
        We ship worldwide. Contact us for a shipping quote and delivery timeframe.
        • +44 (0) 1246 261 999
        • websales@peaksensors.com

        Q: What is a High Temperature Thermocouple Assembly with Ceramic Sheath?
        A: A High Temperature Thermocouple Assembly with Ceramic Sheath is a rare metal thermocouple sensor designed for extremely high-temperature industrial processes. It combines platinum-rhodium thermocouple elements with a ceramic protection sheath to deliver reliable and accurate temperature measurement in harsh operating environments.
        Q: What is the High Temperature Thermocouple Assembly with Ceramic Sheath used for?
        A: The High Temperature Thermocouple Assembly with Ceramic Sheath is commonly used for reliable temperature measurement in extreme high-temperature environments. Typical applications include industrial furnaces, heat treatment processes, ceramics manufacturing, glass production, research and laboratory applications, and other processes operating at elevated temperatures. Its ceramic sheath construction provides excellent thermal stability and protection, making it suitable for demanding applications requiring dependable performance at high temperatures.
        Q: What temperature range can the High Temperature Thermocouple Assembly with Ceramic Sheath measure?
        A: The High Temperature Thermocouple Assembly with Ceramic Sheath is designed to measure temperatures from 0°C to 1700°C, depending on the selected sheath material and thermocouple type.
        Q: Which thermocouple types are available?
        A: Common rare metal thermocouple options include Type R, Type S, and Type B. These thermocouples provide excellent stability and accuracy for high-temperature measurement applications.
        Q: Why is a ceramic sheath used?
        A: Ceramic sheaths provide exceptional resistance to extreme temperatures and harsh process conditions where metallic sheaths may not be suitable. They also help protect the thermocouple elements from contamination and mechanical damage.
        Q: What sheath materials are available?
        A: Available ceramic sheath materials for the High Temperature Thermocouple Assembly include Recrystallised Alumina (Alsint) up to 1700°C, Recrystallised Silicon Carbide up to 1600°C, Sillimanite 60 up to 1600°C, Aluminous Porcelain (Pythagoras) up to 1500°C, Quartz up to 1500°C, Clay Bonded Silicon Carbide up to 1400°C, and Syalon 101 up to 1000°C. Material selection can be matched to the required temperature range and application environment.
        Q: What sheath sizes are available?
        A: Common ceramic sheath diameters for the High Temperature Thermocouple Assembly include Ø6.0 mm, Ø8.0 mm, Ø10.0 mm, Ø12.0 mm, Ø15.0 mm, Ø17.0 mm, Ø20.0 mm, Ø25.0 mm, and Ø28.0 mm. Additional sizes may be available depending on application requirements.
        Q: Can the High Temperature Thermocouple Assembly with Ceramic Sheath be customised?
        A: Available options for the High Temperature Thermocouple Assembly include special sheath materials, lining sheaths for porous materials, shanks fitted for head assemblies, adjustable or welded flanges, pressure-tight construction, probe calibration, and material certification documentation. These options allow the assembly to be customised for demanding high-temperature applications and specific installation requirements.
        Q: What head and connection options are available?
        A: The High Temperature Thermocouple Assembly can be supplied with a range of industrial connection heads, including ALA heads, KNE IP68 heads, HR AL BL flip-top heads, and other custom head options. Different shank materials and assembly configurations are also available to suit specific installation and operating requirements.
        Q: Why choose the High Temperature Thermocouple Assembly with Ceramic Sheath?
        A: The High Temperature Thermocouple Assembly with Ceramic Sheath offers reliable temperature measurement up to 1700°C using platinum-rhodium thermocouple technology. It provides excellent high-temperature stability with multiple ceramic sheath options, customisable construction, and flexible mounting configurations. Suitable for demanding industrial environments, the assembly is available with calibration services and manufactured to meet REACH, RoHS, Conflict Minerals, and ISO 9001 quality standards.

        Bespoke Quote Request

        Fill in and submit the form and we will get back to you with a quote within one working day.
        Alternatively contact us on +44 (0)1246 261999 or websales@peaksensors.com

        "*" indicates required fields

        Name*