Special Options:
- Duplex
- Higher accuracy sensors A, 1/3,1/5,1/10 DIN
- Pt 50, Pt 500, Pt 1000 and Pt 2000, Cu or Ni element
- 2 or 4 wires
- Compression fitting
- Tagging
- RT can be replaced with a thermistor
- Material Certificates
| Type Designation: |
TRD
|
| Temperature Range: |
-100 to 230°C
|
| Common Sensor Types: |
1 Pt 100 B
|
| Temperature Coefficient: |
0.3850 ohms/° C
|
| Wiring: |
3 wire, marked red/red/white
|
| Common Diameters: |
Ø 6.0, 8.0mm
|
| Common Sheaths: |
316 SS
|
| Head Connection: |
M4 Screws 33mm PCD
|
| Cold End Max Temperature: |
150 ° C
|
| Tail Detail: |
75mm tails, 10mm tinned
|
Delivery time: 1 week, subject to stock availability.
We ship to the following countries:
United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States
Shipping rates:
• £15 for orders from UK Mainland.
• £25 for orders from UK – Highlands & Islands.
• £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
• £37 for orders from France and Germany.
• £42 for orders from Switzerland.
• £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
• £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
• £49 for orders from Iceland.
• £51 for orders from Finland, Sweden and Greece.
• £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
• £61 for orders from United States and Canada.
• £63 for orders from Liechtenstein.
• £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
• £90 for orders from India.
• £103 for orders from Brazil.
Don’t see your country listed?
We ship worldwide. Contact us for a shipping quote and delivery timeframe.
• +44 (0) 1246 261 999
• websales@peaksensors.com
Q: What is a Resistance Thermometer Insert with DIN Plate?
A: A Resistance Thermometer Insert with DIN Plate is an RTD sensor insert designed for installation into temperature heads and thermowells. The DIN plate mounting arrangement allows users to fit an existing transmitter directly to the insert for industrial temperature measurement applications.
Q: What is the Resistance Thermometer Insert with DIN Plate used for?
A: The Resistance Thermometer Insert with DIN Plate is commonly used for head-mounted transmitter assemblies, thermowell installations, pocket and head assemblies, industrial process temperature monitoring, and plant maintenance or sensor replacement applications.
Q: What temperature range can the Resistance Thermometer Insert with DIN Plate measure?
A: The Resistance Thermometer Insert with DIN Plate is designed to operate over a temperature range of -100°C to +230°C.
Q: What sensor element is commonly supplied?
A: The insert is commonly supplied with a Pt100 Class B thin-film RTD element featuring a temperature coefficient of 0.3850 ohms/°C.
Q: Why is the DIN Plate version suitable for transmitter installations?
A: The DIN Plate design allows customers to mount an existing transmitter directly onto the insert, providing a convenient and cost-effective solution for industrial temperature measurement systems.
Q: What sheath materials and diameters are available?
A: Standard specifications for the Resistance Thermometer Insert with DIN Plate include a 316 Stainless Steel sheath with Ø6.0 mm and Ø8.0 mm diameter options. These provide durability and corrosion resistance across a wide range of industrial environments.
Q: What wiring configuration is supplied as standard?
A: The Resistance Thermometer Insert with DIN Plate is typically supplied as a 3-wire RTD with red/red/white conductor identification. Alternative 2-wire and 4-wire versions are available.
Q: What connection arrangement does the insert use?
A: The Resistance Thermometer Insert with DIN Plate features a standard DIN mounting arrangement with M4 fixing screws and a 33 mm pitch circle diameter (PCD), ensuring compatibility with many industrial transmitter and connection head designs.
Q: What customisation options are available?
A: Available options for the Resistance Thermometer Insert with DIN Plate include duplex sensor configurations, higher accuracy RTDs (Class A, 1/3, 1/5, and 1/10 DIN), Pt50, Pt500, Pt1000, and Pt2000 elements, copper and nickel sensor elements, 2-wire or 4-wire configurations, compression fittings, thermistor alternatives, product tagging, and material certification documentation.
Q: Why choose the Resistance Thermometer Insert with DIN Plate?
A: The Resistance Thermometer Insert with DIN Plate offers easy integration with existing transmitters and cost-effective industrial temperature measurement. It features a standard DIN mounting arrangement, durable 316 stainless steel construction, operating temperatures from -100°C to +230°C, and multiple RTD and wiring options. Manufactured to meet REACH, RoHS, Conflict Minerals, and ISO 9001 quality standards.