Delivery time: 1-2 working days.
We ship to the following countries:
United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States
Shipping rates:
• £15 for orders from UK Mainland.
• £25 for orders from UK – Highlands & Islands.
• £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
• £37 for orders from France and Germany.
• £42 for orders from Switzerland.
• £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
• £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
• £49 for orders from Iceland.
• £51 for orders from Finland, Sweden and Greece.
• £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
• £61 for orders from United States and Canada.
• £63 for orders from Liechtenstein.
• £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
• £90 for orders from India.
• £103 for orders from Brazil.
Don’t see your country listed?
We ship worldwide. Contact us for a shipping quote and delivery timeframe.
• +44 (0) 1246 261 999
• websales@peaksensors.com
Q: What is an 8mm OD x 5mm ID Recrystalised Alumina Tube with open ends used for?
A: This recrystalised alumina tube is designed to provide electrical insulation and mechanical protection for thermocouple wires and temperature sensor assemblies operating in high-temperature environments. The open-both-ends design allows conductors to pass through the full length of the tube, making it suitable for furnaces, kilns, heat treatment systems, and custom thermocouple assemblies.
Q: What is the difference between an open-ended and a closed-end recrystalised alumina tube?
A: An open-ended tube is used to protect and insulate thermocouple conductors along their entire length, while a closed-end tube is designed to protect the thermocouple sensing junction from direct exposure to the process environment. Open-ended tubes are typically used when the thermocouple junction is located outside the tube or protected separately.
Q: Why choose recrystalised alumina instead of aluminous porcelain?
A: Recrystalised alumina offers higher purity, improved thermal stability, and greater resistance to extreme temperatures than aluminous porcelain. It is commonly selected for demanding industrial applications where long-term reliability, reduced contamination risk, and stable thermocouple performance are required.
Q: Which thermocouple types can be used with this tube?
A: This tube is suitable for use with a wide range of thermocouple types, including Type K, Type N, Type R, Type S, and other thermocouples used in high-temperature applications. It provides reliable insulation and protection for thermocouple conductors operating in harsh thermal environments.
Q: Why would I choose an 8mm OD x 5mm ID tube?
A: The 8mm outer diameter offers a good balance between mechanical strength and installation flexibility, while the 5mm internal diameter provides sufficient space for many standard thermocouple assemblies. This size is often chosen where a compact but durable protection solution is required.
Q: Is this tube suitable for furnace and kiln applications?
A: Yes. Recrystalised alumina tubes are widely used in furnaces, kilns, heat treatment plants, laboratory ovens, and thermal processing systems because they maintain their structural integrity and insulation properties at very high temperatures.
Q: Can this ceramic tube withstand repeated heating and cooling cycles?
A: Yes. Recrystalised alumina provides excellent thermal stability and is commonly used in applications involving repeated temperature cycling. It performs well in demanding thermal environments where long-term durability and consistent performance are important.
Q: When should I choose an open-ended tube instead of ceramic insulator beads?
A: An open-ended tube is generally preferred when continuous insulation and protection are required along the full length of a thermocouple assembly. Ceramic beads are typically used to separate individual conductors, whereas a tube provides both mechanical protection and electrical insulation in a single component.
Q: Which industries commonly use recrystalised alumina tubes?
A: These tubes are widely used in heat treatment, steel production, ceramics manufacturing, glass processing, aerospace, power generation, research laboratories, and industrial furnace applications where thermocouples operate in extreme temperature conditions.
Q: What advantage does the 5mm internal diameter provide?
A: The 5mm internal bore offers enough space for many standard thermocouple assemblies while maintaining a compact overall tube size. This allows engineers to create robust temperature measurement systems without increasing the installation footprint unnecessarily.