15mm OD x 10mm ID – Recrystalised Alumina Tube – Open Both Ends

From: £82.15 - £124.86 Exc VAT

A pure and tough ceramic exhibiting hardness and vacuum tightness. Excellent in oxidising and reducing atmospheres. Fair thermal shock resistance. Often used in rare metal thermocouples.

  • Equivalent to Alsint
  • Basic Composition: Al2O3 99.7%
  • Temperature Limits: 1700°C
  • International Standards: DIN VDE 0335 C799
  • Density: 3.9 g/cm³
  • Melting Range: 2072°C
  • Coefficient of Expansion: 8 x10-6 / ° C
  • Thermal Conductivity: 26 W/m ° C
  • Length and Diameter Tolerance: DIN 40680 Medium

Delivery time: 1-2 working days.

Compliance:
✔ RoHS 3 (2015/863)
✔ Mineral Conflict
✔ ISO 9001 Certified

PQAL black on white ukas 9001 logo

- +
Need some help?
Call us: +44 (0) 1246 261 999 websales@peaksensors.com

"*" indicates required fields

Name*

Similar Products

0
    0
    Your Basket
    Your basket is emptyReturn to Shop
        Scroll to Top
        Secret Link

        Shipping Information

        FAQs

        Quote Request

        Delivery time: 1-2 working days.

        We ship to the following countries:
        United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States

        Shipping rates:
        • £15 for orders from UK Mainland.
        • £25 for orders from UK – Highlands & Islands.
        • £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
        • £37 for orders from France and Germany.
        • £42 for orders from Switzerland.
        • £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
        • £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
        • £49 for orders from Iceland.
        • £51 for orders from Finland, Sweden and Greece.
        • £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
        • £61 for orders from United States and Canada.
        • £63 for orders from Liechtenstein.
        • £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
        • £90 for orders from India.
        • £103 for orders from Brazil.

        Don’t see your country listed?
        We ship worldwide. Contact us for a shipping quote and delivery timeframe.
        • +44 (0) 1246 261 999
        • websales@peaksensors.com

        Q: What is a 15mm OD x 10mm ID Recrystalised Alumina Tube with open ends used for?
        A: This recrystalised alumina tube is designed to provide electrical insulation and mechanical protection for thermocouple wires and temperature sensor assemblies operating in high-temperature environments. The open-both-ends design allows conductors to pass through the full length of the tube, making it suitable for furnaces, kilns, heat treatment equipment, and custom thermocouple assemblies.
        Q: What is the difference between an open-ended and a closed-end recrystalised alumina tube?
        A: An open-ended tube is primarily used to protect and insulate thermocouple wires along their length, while a closed-end tube is designed to shield the thermocouple measuring junction from direct exposure to the process environment. Open-ended tubes are commonly used in replacement thermocouples and custom-built sensor assemblies.
        Q: Why choose recrystalised alumina instead of standard ceramic materials?
        A: Recrystalised alumina offers excellent thermal stability, high purity, superior electrical insulation, and exceptional resistance to high temperatures. These properties make it a popular choice for demanding industrial applications where reliable thermocouple protection is required over extended operating periods.
        Q: Which thermocouple types are suitable for use with this tube?
        A: This tube can be used with a wide range of thermocouple types including Type K, Type N, Type R, Type S, and other high-temperature thermocouples. It is particularly suitable for installations where thermocouple wires require protection in extreme thermal environments.
        Q: Why would I choose a 15mm OD x 10mm ID tube?
        A: The 15mm outer diameter provides increased mechanical strength and durability, while the 10mm internal diameter allows accommodation of larger thermocouple assemblies, twin-element sensors, and additional insulating components. This makes it suitable for more demanding industrial applications.
        Q: Is this tube suitable for furnace and heat treatment applications?
        A: Yes. Recrystalised alumina tubes are widely used in heat treatment plants, industrial furnaces, kilns, and laboratory heating systems because they can withstand very high operating temperatures while maintaining excellent electrical insulation properties.
        Q: Can this ceramic tube withstand repeated temperature cycling?
        A: Yes. Recrystalised alumina offers excellent thermal stability and performs well in applications involving repeated heating and cooling cycles. While excessive thermal shock should always be minimised, the material is designed for demanding thermal environments.
        Q: When should I choose an open-ended tube instead of a closed-end tube?
        A: An open-ended tube is the right choice when you need to insulate and protect thermocouple wires throughout their length. A closed-end tube is generally preferred when the thermocouple measuring junction itself requires protection from direct contact with process gases, dust, or contaminants.
        Q: Which industries commonly use recrystalised alumina tubes?
        A: Recrystalised alumina tubes are commonly used in heat treatment, steel production, glass manufacturing, ceramics processing, aerospace, power generation, laboratory testing, and industrial furnace applications where reliable high-temperature thermocouple protection is essential.
        Q: What advantage does the 10mm internal diameter provide?
        A: The 10mm internal bore provides additional installation flexibility for larger thermocouple assemblies, dual-element sensors, and ceramic insulated conductor arrangements. This helps engineers build robust temperature measurement systems for demanding industrial applications while maintaining excellent mechanical protection.