12mm OD x 8mm ID – Recrystalised Alumina Tube – Open Both Ends

From: £44.96 - £94.88 Exc VAT

A pure and tough ceramic exhibiting hardness and vacuum tightness. Excellent in oxidising and reducing atmospheres. Fair thermal shock resistance. Often used in rare metal thermocouples.

  • Equivalent to Alsint
  • Basic Composition: Al2O3 99.7%
  • Temperature Limits: 1700°C
  • International Standards: DIN VDE 0335 C799
  • Density: 3.9 g/cm³
  • Melting Range: 2072°C
  • Coefficient of Expansion: 8 x10-6 / ° C
  • Thermal Conductivity: 26 W/m ° C
  • Length and Diameter Tolerance: DIN 40680 Medium

Delivery time: 1-2 working days.

Compliance:
✔ RoHS 3 (2015/863)
✔ Mineral Conflict
✔ ISO 9001 Certified

PQAL black on white ukas 9001 logo

- +
Need some help?
Call us: +44 (0) 1246 261 999 websales@peaksensors.com

"*" indicates required fields

Name*

Similar Products

0
    0
    Your Basket
    Your basket is emptyReturn to Shop
        Scroll to Top
        Secret Link

        Shipping Information

        FAQs

        Quote Request

        Delivery time: 1-2 working days.

        We ship to the following countries:
        United Kingdom, Austria, Belgium, Bosnia and Herzegovina, Brazil, Bulgaria, Canada, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, India, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United States

        Shipping rates:
        • £15 for orders from UK Mainland.
        • £25 for orders from UK – Highlands & Islands.
        • £35 for orders from Belgium, Ireland, Luxembourg and Netherlands.
        • £37 for orders from France and Germany.
        • £42 for orders from Switzerland.
        • £43 for orders from Austria, Denmark, Italy, Portugal and Spain.
        • £45 for orders from Czech Republic, Slovakia, Slovenia and Bulgaria.
        • £49 for orders from Iceland.
        • £51 for orders from Finland, Sweden and Greece.
        • £53 for orders from Croatia, Estonia, Hungary, Poland, Latvia, Lithuania and Romania.
        • £61 for orders from United States and Canada.
        • £63 for orders from Liechtenstein.
        • £72 for orders from Bosnia and Herzegovina, Norway and Serbia.
        • £90 for orders from India.
        • £103 for orders from Brazil.

        Don’t see your country listed?
        We ship worldwide. Contact us for a shipping quote and delivery timeframe.
        • +44 (0) 1246 261 999
        • websales@peaksensors.com

        Q: What is a 12mm OD x 8mm ID Recrystalised Alumina Tube with open ends used for?
        A: This recrystalised alumina tube is used to provide electrical insulation and mechanical protection for thermocouple wires and sensor assemblies operating in high-temperature environments. The open-both-ends design allows conductors to pass through the entire tube length, making it suitable for furnaces, kilns, heat treatment plants, and custom thermocouple installations.
        Q: What is the difference between an open-ended and a closed-end recrystalised alumina tube?
        A: An open-ended tube is designed to protect and insulate thermocouple conductors along their length, while a closed-end tube is intended to protect the thermocouple measuring junction from direct exposure to the process atmosphere. Open-ended tubes are commonly used in custom sensor assemblies and replacement thermocouple installations.
        Q: Why use recrystalised alumina instead of aluminous porcelain?
        A: Recrystalised alumina provides higher purity, improved thermal stability, and better performance at extreme temperatures compared with aluminous porcelain. It is often chosen for applications where thermocouples operate continuously at elevated temperatures and reliable long-term performance is required.
        Q: Which thermocouple types can be used with this tube?
        A: This tube is suitable for a wide range of thermocouple types, including Type K, Type N, Type R, Type S, and other high-temperature thermocouples. It is commonly used wherever thermocouple wires require insulation and protection in demanding thermal environments.
        Q: Why would I choose a 12mm OD x 8mm ID tube?
        A: The 12mm outer diameter provides increased mechanical strength compared with smaller tubes, while the 8mm internal diameter allows accommodation of larger thermocouple assemblies, twin-element sensors, and additional insulation materials used in industrial temperature measurement systems.
        Q: Is this tube suitable for furnace and heat treatment applications?
        A: Yes. Recrystalised alumina tubes are widely used in industrial furnaces, heat treatment systems, kilns, and laboratory ovens because they offer excellent temperature resistance and maintain their insulating properties at elevated operating temperatures.
        Q: Can this tube withstand repeated heating and cooling cycles?
        A: Recrystalised alumina offers excellent thermal stability and is commonly used in applications involving repeated temperature cycling. It performs well in demanding thermal processes where long-term reliability and resistance to thermal degradation are important.
        Q: When should I choose an open-ended tube instead of a closed-end tube?
        A: An open-ended tube should be chosen when the goal is to protect and insulate thermocouple wires along their length. A closed-end tube is generally preferred when the thermocouple junction itself requires protection from direct contact with gases, dust, or process materials.
        Q: Which industries commonly use recrystalised alumina tubes?
        A: Recrystalised alumina tubes are commonly used in heat treatment, aerospace, ceramics manufacturing, glass production, steel processing, power generation, research laboratories, and industrial furnace applications where thermocouples are exposed to extreme temperatures.
        Q: What advantage does the 8mm internal diameter provide?
        A: The 8mm internal bore provides additional space for larger thermocouple assemblies, multi-element sensors, and extra insulation components. This makes it suitable for applications where flexibility in sensor design and robust thermocouple protection are required.

        Bespoke Quote Request

        Fill in and submit the form and we will get back to you with a quote within one working day.
        Alternatively contact us on +44 (0)1246 261999 or websales@peaksensors.com

        "*" indicates required fields

        Name*